R221A08 12V DC 8CH Serial Port Relay DB9 UART RS232 Switch untuk Kontrol Pencahayaan Rumah Pemanas Air Listrik

USD 17.22USD 24.95

R221A08 12V DC 8CH Serial Port Relay DB9 UART RS232 Switch untuk Kontrol Pencahayaan Rumah Pemanas Air Listrik

Description
Product Name: R221A08 12V DC 8CH Serial Port Relay DB9 UART RS232 Switch For Control Home Lighting Electric Water Heater
 
Package inlcuded:
 
1 x DC 12V 8Ch RS232 Relay Board
 
 
 
Description:
 
 
 
 
 
8 Channel Relay Module;
 
 
 
Power input: DC 12V(8.5-13.5V).
 
 
 
Standby current (all relays closed) 18MA, 1 relay open 51MA, 2 relays open 82MA, 3 relays open 112MA, 4 relays open 142MA, 5 relays open 170MA , 6 relays open 198MA , 7 relays open 227MA , 8 relays open 251MA
 
 
 
PC Serial ports RS232 Control Relay;
 
 
 
Power indicator : LED lights;
 
 
 
Output indication : relay output with LED indicators,easy to see working status of the relay;
 
 
 
Communication protocol: UART protocol communication, baud rate 9600kpbs, 8 data bits, one stop bit, no parity. Each data frame contains eight bytes. Two-way data transmission.
 
 
 
Baud rate 9600kbps, 8 data bits, one stop bit, no parity. Each data frame contains eight bytes.
 
 
 
Size : 94mm*62mm*19mm
 
 
 
Weight : 120g
 
 
For more information, please contact me
 
 
 
 
1 Control commands:
 
 
 
1. Reading status(reading the satus of the relay (on/off))
 
 
 
 
Channel 1 :55 56 00 00 00 01 00 AC
 
Channel 2 :55 56 00 00 00 02 00 AD
 
Channel 3 :55 56 00 00 00 03 00 AE
 
Channel 4 :55 56 00 00 00 04 00 AF
 
Channel 5 :55 56 00 00 00 05 00 B0
 
Channel 6 :55 56 00 00 00 06 00 B1
 
Channel 7 :55 56 00 00 00 07 00 B2
 
Channel 8 :55 56 00 00 00 08 00 B3
 
 
2.Relay open (issue this command,Relay open,COM connect to NO)
 
 
 
 
Channel 1 :55 56 00 00 00 01 01 AD
 
Channel 2 :55 56 00 00 00 02 01 AE
 
Channel 3 :55 56 00 00 00 03 01 AF
 
Channel 4 :55 56 00 00 00 04 01 B0
 
Channel 5 :55 56 00 00 00 05 01 B1
 
Channel 6 :55 56 00 00 00 06 01 B2
 
Channel 7 :55 56 00 00 00 07 01 B3
 
Channel 8 :55 56 00 00 00 08 01 B4
 
 
 
 
3. Relay close (issue this command,Relay close,COM disconnect NO,and COM connect to NC)
 
 
 
 
 
 
 
Channel 1 :55 56 00 00 00 01 02 AE
 
Channel 2 :55 56 00 00 00 02 02 AF
 
Channel 3 :55 56 00 00 00 03 02 B0
 
Channel 4 :55 56 00 00 00 04 02 B1
 
Channel 5 :55 56 00 00 00 05 02 B2
 
Channel 6 :55 56 00 00 00 06 02 B3
 
Channel 7 :55 56 00 00 00 07 02 B4
 
Channel 8 :55 56 00 00 00 08 02 B5
 
 
 
 
4. Relay toggle(Relay status reversal,if COM connect to NO,this commands will Disconnect COM to NO and Reverse COM connect to NC,and vice versa)
 
 
 
 
 
 
 
 
Channel 1 :55 56 00 00 00 01 03 AF
 
Channel 2 :55 56 00 00 00 02 03 B0
 
Channel 3 :55 56 00 00 00 03 03 B1
 
Channel 4 :55 56 00 00 00 04 03 B2
 
Channel 5 :55 56 00 00 00 05 03 B3
 
Channel 6 :55 56 00 00 00 06 03 B4
 
Channel 7 :55 56 00 00 00 07 03 B5
 
Channel 8 :55 56 00 00 00 08 03 B6
 
 
 
 
5. Relay momentary(Relay COM connect to NO,disconnect after 200MS)
 
 
 
 
Channel 1 :55 56 00 00 00 01 04 B0
 
Channel 2 :55 56 00 00 00 02 04 B1
 
Channel 3 :55 56 00 00 00 03 04 B2
 
Channel 4 :55 56 00 00 00 04 04 B3
 
Channel 5 :55 56 00 00 00 05 04 B4
 
Channel 6 :55 56 00 00 00 06 04 B5
 
Channel 7 :55 56 00 00 00 07 04 B6
 
Channel 8 :55 56 00 00 00 08 04 B7
 

 

6. Relay Interlock

 
Channel 1 :55 56 00 00 00 01 05 B1
 
Channel 2 :55 56 00 00 00 02 05 B2
 
Channel 3 :55 56 00 00 00 03 05 B3
 
Channel 4 :55 56 00 00 00 04 05 B4
 
Channel 5 :55 56 00 00 00 05 05 B5
 
Channel 6 :55 56 00 00 00 06 05 B6
 
Channel 7 :55 56 00 00 00 07 05 B7
 
Channel 8 :55 56 00 00 00 08 05 B8
 
 
 
 
 
Once issue a command,will have a return fame,7th byte of return fame mean the satus of realy.
 
 
 
2 return command
 
 
1.Return relay open(return this command,mean COM connect to NO)
 
 
 
 
Channel 1 :33 3C 00 00 00 01 01 71
 
Channel 2 :33 3C 00 00 00 02 01 72
 
Channel 3 :33 3C 00 00 00 03 01 73
 
Channel 4 :33 3C 00 00 00 04 01 74
 
Channel 5 :33 3C 00 00 00 05 01 75
 
Channel 6 :33 3C 00 00 00 06 01 76
 
Channel 7 :33 3C 00 00 00 07 01 77
 
Channel 8 :33 3C 00 00 00 08 01 78
 
 
 
 
 
 
 
2.Return relay close(return this command,mean COM disconnect NO , and COM connect to NC)
 
 
 
 
Channel 1 :33 3C 00 00 00 01 02 72
 
Channel 2 :33 3C 00 00 00 02 02 73
 
Channel 3 :33 3C 00 00 00 03 02 74
 
Channel 4 :33 3C 00 00 00 04 02 75
 
Channel 5 :33 3C 00 00 00 05 02 76
 
Channel 6 :33 3C 00 00 00 06 02 77
 
Channel 7 :33 3C 00 00 00 07 02 78
 
Channel 8 :33 3C 00 00 00 08 02 79
 
 
 
 
Instruction manual Please ask us after the purchase
 
 
 
ApplicationRemote control, remote measurement system; Wireless meter ;
 
Smart Home,Home Automation ,Wiser Home;Access control ;Identification system ;Data collection; IT household appliance ;Intelligence household appliance;Baby monitoring system;
 
 
 
Typial application :
 
 
 
1 DC 12V control circuit,Wiring diagram below. ''LOAD'' may be LED lights, fans, motors and other DC 12V equipment
 
 
 
 
 
 
 
 
 
 
2 DC 1-48V OR AC 85-265V control circuit,Wiring diagram below(Note:If not DC 12V load, need another DC 12V power supply). ''LOAD'' may be LED lights, fans, motors and other DC AC equipment
 
 
 
 
 
 
 
 
 
 
 
 
Test Software:(Only support win xp (32/62) win 7 (32/62) Operating System)
 
 
 
 
 
 

 

 

 

Specification

is_customized : Yes

Origin : Mainland China

Contact Load : High Power

Brand Name : eletechsup

Protect Feature : Sealed

Voltage : 12V

Theory : Electromagnetic Relay

Power Source : DC

Usage : General Purpose

Model Number : R221A08

Size : Miniature

Certification : NONE

+